Data Center Facilities and HVAC Design


CPD Courses and Further Learning in

(1) Data Center Facilities Design & Infrastructure Engineering
(2) Electrical Design for Mission Critical Supply
(3) Air Conditioning System Design for Data Center
(4) Project Management for Data Center & Critical Facilities: From Design to Commissioning


Overview

The American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE) Technical
Committee (TC) 9.9 has published 10 guidelines covering a wide range of data center design and operational issues. These ASHRAE works are also referenced in the TIA-942 data center standard.

We provide an introduction of critical infrastructure system that supports typical data centers and prepare individual to fully understand the main components that facilitate data centre design & build by exploring the standards of TIA-942 and Uptime Tier Levels.

Furthermore, we detail about the key challenges and consider different criteria, from design, testing, commissioning, sustainability and efficiency, of HVAC (Heating, Ventilation, and Air Conditioning) system in a data center.

You will understand the design and maintenance issues of a mission critical supply system, from power components to distributions and efficiency.

All sections are designed for data center management, operators, building services engineers, facilities and E&M professionals, etc. to enrich the relevant knowledge in critical facilities / data center design and build.




Part 1 - Data Center Facilities Design & Infrastructure Engineering (2-day)


- Data Centre Overview and Definition
- Data Centre Standards (TIA and Tier)
- Data Centre Network and Structure
- IT Strategy
- Cabinet Layout
- Raised Floor System
- Telecommunication Backbones, Redundancy, Sizing and Planning
- Fiber and Optical System Design
- Fiber and Optical Cable Components
- Copper System Design and High Speed Ethernet
- Copper Cabling Components
- Cable Distribution, Layout and Management
- Cooling - Cooling Topologies, Chiller, CRAC, Cooling Towers, Hot / Cold Aisle, etc.
- Power - High / Low Power, Switch System, UPS, Transformers, Fuel Tanks, Generators, etc.
- Earthing / Grounding and Bounding
- Electromagnetic Interference / Electromagnetic Pulse (EMI / EMP)
- Environmental Management System (EMS)
- Fire Protection System
- Physical Security


DOWNLOAD DETAILED SYLLABUS




Part 2 - Electrical Design for Mission Critical Supply (2-day)


- Concept on primary supply and secondary supply
- Power flow in mission critical supply system
- Features of major equipment for critical supply :

* Uninterrupted power supply and power storage
* Backup generator
* Automatic transfer switch
* Static transfer switch
* Isolation transformer

- Efficiency assessment
- Power quality review
- Configuration diagram of critical supply (N+1 / 2N) design & analysis
- Review of cable sizing to incorporate harmonics content
- Earthing system design
- Testing and commissioning requirements
- Brief of Systems Merging Appraisal Test (SMAT)


DOWNLOAD DETAILED SYLLABUS




Part 3 - Air Conditioning System Design for Data Center (2-day)



Datacom Equipment Power Trends
and Cooling Applications

- load trends and their application
- air cooling of computer equipment
- liquid cooling of computer equipment

Design Consideration

- design criteria
- HVAC load
- computer room cooling
- air distribution
- liquid cooling
- availability and redundancy
- integration with other MEP system
- controls
- computer fluid dynamics (CFD)

Testing and Commissioning

- air cleanliness test
- heat load test
- factory acceptance test
- site acceptance test
- integrated performance test (IST)

Sustainable Design

- combined heat power plant (CHP)
- solar cooling
- geothermal cooling
- evaporative cooling
- air side economizers
- desiccant unit

Energy Efficiency

- power usage effectiveness
- chilled water plant optimization
- water side and air side equipment
- part load operation
- controls and energy management
- LEED certified data center
- building energy code

 

DOWNLOAD DETAILED SYLLABUS




Part 4 - Project Management for Data Center & Critical Facilities: From Design to Commissioning (2-day)


- Reviewing the Project Management Basics

* Planning and Programming a Successful Project for Mission-critical Purposes
* Managing a Project on Time, Cost and Quality

- Contract Management for Data Center Design and Build
- Roles and Responsibilities
- Liaising with Clients (Facility Owners, Project Owners, etc.)
- Liaising with Stakeholders
- Liaising with Design Consultants / Architect
- Managing Facilities / Services Suppliers
- Managing Contractors
- Assessing the Project Progression and Status Meetings
- Conflicts Management
- Change Management and Accommodation
- Project Handover, Testing and Commissioning
- Cases Study


DOWNLOAD DETAILED SYLLABUS




Registration Details

Course Dates

Part 1 -
Data Center Facilities Design and Infrastructure Engineering

Schedule to be announced very soon (2-day)

Part 2 -
Electrical Design for Mission Critical Supply

Schedule to be announced very soon (2-day)

Part 3 -
Air Conditioning System Design for Data Center

Schedule to be announced very soon (2-day)

Part 4 -
Project Management for Critical Facilities from Design to Commissioning

Schedule to be announced very soon (2-day)

Language Cantonese (with English course materials); or
English (for overseas or non-Cantonese-speaking participants)
Time 10:00am - 5:30pm
Venue 19/F, New Victory House (OfficePlus), 93 - 103 Wing Lok Street, Sheung Wan, Hong Kong
Target Audience CIO, CTO, IT Directors, Data Center Operations / Facilities Managers, Data Center / ICT Consultants, E&M Engineers, etc.
Fee
(per 2-day course)

Normal Rate: HK$4,700 per head (10% Early Bird Discount Available)
Special Rate: HK$4,030 per head (CIBSE / HKIE All Membership Classes)

Enrollment Online Registration or Download Application Form
Certification

Individual CPD / completion certificate can be granted by our experienced Chartered Engineers.


Strategic Media Asia (SMA) is one of the approved CPD course providers of the Chartered Institution of Building Services Engineers (CIBSE).

Should you have any enquiry, please feel free to contact (852) 2117 3893 / info@stmedia-asia.com. Kindly visit our website (www.stmedia-asia.com) for other technical training seminars.

Delivered by Experienced Speakers

All sections are conducted by Chartered Engineers (CEng) who help you to approach the best practices in designing and operating an energy efficient data center.


Ir C.K. Chan
CEng, CEnv, FSOE, FIplantE, MIET, MHKIE, CSME, REW H0 C0

Ir Edmond Fok
BEng(Hons), MSc, REA, RSO, IntPE, CEnv, CEng, FCIBSE, FSOE, FIPlantE, MHKIE

Mr. Joe Tang
BEng (Hons), MSc, CEng, MCIBSE, MIET, MASHRAE


For detailed profile of the instructor team, please visit our website (www.stmedia-asia.com)


Knowledge Blog & Community

Join our community and visit the knowledge blog featuring critical facilities and data center design considerations, energy saving and efficiency management.

SMA @ Facebook SMA @ Twitter SMA @ Linkedin SMA @ Blogger


© 2017 Strategic Media Asia Limited - Connecting IT, Facilities and Design

T (852) 2117 3893 | F (852) 2184 9978 | www.stmedia-asia.com
Rm 403, 4th Floor, Dominion Centre, 43 - 59 Queen's Road East, Hong Kong