CPD Courses
and Further Learning in
Air
Conditioning System Design for Critical Infrastructure
|
|
Overview
|
The American Society of Heating, Refrigeration
and Air-Conditioning Engineers (ASHRAE) Technical Committee (TC) 9.9 has
published 10 guidelines covering a wide range of mission-critical
facilities design and operational issues. These ASHRAE works are also
referenced in the TIA-942 data center standard.
We provide an introduction of infrastructure system that supports critical
services and prepare individual to fully understand the main components
that facilitate the whole system (including data centers) design &
build by exploring the standards of TIA-942 , Uptime Tier Levels, etc.
Furthermore, we detail about the key challenges and consider different
criteria, from design, testing, commissioning, sustainability and
efficiency, of HVAC (Heating, Ventilation, and Air Conditioning) system in
a data center / critical infrastructure.
You will understand the design and maintenance issues of a mission-critical
supply system, from power components to distributions and efficiency.
All sections are designed for data center and facilities management,
operators, building services engineers, infrastructure design
professionals, etc. to enrich the relevant knowledge in critical system and
data center design & build.
|
|
Air Conditioning
System Design for Critical Infrastructure (2-day)
Datacom
Equipment Power Trends
and Cooling Applications
-
load trends and their application
- air cooling of computer equipment
- liquid cooling of computer equipment
Design Consideration
- design criteria
- HVAC load
- computer room cooling
- air distribution
- liquid cooling
- availability and redundancy
- integration with other MEP system
- controls
- computer fluid dynamics (CFD)
Testing and Commissioning
- air cleanliness test
- heat load test
- factory acceptance test
- site acceptance test
- integrated performance test (IST)
|
Sustainable
Design
-
combined heat power plant (CHP)
- solar cooling
- geothermal cooling
- evaporative cooling
- air side economizers
- desiccant unit
Energy Efficiency
- power usage effectiveness
- chilled water plant optimization
- water side and air side equipment
- part load operation
- controls and energy management
- LEED certified data center
- building energy code
DOWNLOAD DETAILED
SYLLABUS
|
|
Registration
Details
|
Course Dates
|
12 & 13 October 2022 (Wed. & Thur.) [Round 24]
|
Language
|
Cantonese (with English course materials); or
English (for overseas or non-Cantonese-speaking participants)
|
Time
|
10:00 ~ 17:00
|
Venue
|
(TBA)
|
Target Audience
|
IT / Data Center Operations / Facilities Managers,
Data Center Design Consultants, E&M Engineers, System Architects
(Infrastructure), etc.
|
Fee
(per 2-day course)
|
Normal
Rate: HK$4,230 per
head; or HK$4,030 per head
for (1) all membership classes of HKIE / CIBSE / professional
organizations in engineering; or (2) HK$3,830 per head for more than 5 enrollments made at the
same time
|
|
|
|
Should you have any enquiry, please feel free to
contact (852) 2117 3893 / info@stmedia-asia.com. Kindly visit our website (www.stmedia-asia.com)
for other technical training seminars.
|
|
Experienced
Speakers
|
The course is conducted by Chartered Engineers
(CEng) who help you to approach the best practices in designing and
operating an energy efficient data center.
Professor Ir Dr. Lip, Samuel
Associate Professor in Chu Hai College of Higher Education,
BSc (Hons), PgDip, MSc, PhD, CEng, RPE, FCIBSE, FIMechE, FCIPHE, FIEAust (M&EColleges),
MIET, MIFireE, MASHRAE, FCABE, MAIB, MHKIE, MCIH, MHKICM, REA,
REW (C0), RCx Pro, QP (WSD), MHIREA, PMP (Tier 1) Licence
For detailed profile of the instructor team, please visit our website (www.stmedia-asia.com)
|
|
|
Knowledge
Blog & Community
|
Join
our community and visit the knowledge blog featuring critical facilities
and data center design considerations, energy saving and efficiency
management.
 
|
|
|
|
|
©
Strategic Media Asia Limited - Connecting IT, Facilities and Design
T
(852) 2117 3893 | F (852) 2310 4739 | www.stmedia-asia.com
Unit 702, 7th Floor, The Cloud, Tai Kok Tsui, Kowloon, Hong Kong
|
|

|